Flow Range: 0.11 to 0.66 GPM, Square Wave (Pulse) Output, 5-24VDC Power Supply Required

DigiflowX3 Oval Gear Flow Sensor

ULF Oval Gear Meter


New Page 2

NOTE: Although these flow sensors are an established product with a long service history in Europe, they are new to our product offering. Consequently, delivery times may vary until the market for this product is established. If lead time is critical to your installation, please call us for a current lead time.

Type F3.80
Low Flow Oval Gear Sensors

The Type F3.80 Oval Gear Flow Sensors are positive displacement flow meters suitable for high viscosity fluids up to 1,000cP. Accuracy and repeatability are high.

Inside is a transducer and two oval gears oriented at 90 degrees to each other with embedded permanent magnets. A square wave output signal is generated with frequency proportional to the rate of rotor rotation and flow velocity. This pulse output is normally fed to FlowX3 Flow Monitor/Transmitter or Batch Controller. It can also be fed to other brands instruments or PLC's .

Benefits:

  • High Accuracy and Repeatability

  • Excellent choice for Low Flows of High Viscosity Fluids

  • Suitable for Pulsating Flows


Polypropylene
(PP) Version

ECTFE (Halar)
Version

316L SS
Version
Sensor Body: PP ECTFE 316L SS
Oval Gears: ECTFE ECTFE ECTFE
Shaft: Zirconium Zirconium 316L SS
O-Rings: Viton Viton Viton
Connections:

Inline 1/4" BSP male threaded

Flow Ranges:
F3.81 0.044 - 0.44 GPM / 10 - 100 LPH
F3.82 0.11 - 0.66 GPM / 25 - 150 LPH

Technical - General:

Supply Voltage: 5 to 24 VDC regulated
Supply Current: < 15 mA @ 24 VDC
Output Signal: Square Wave (Pulse)
Electrical Class: NEMA 4, 4X
Accuracy: < 1% of Reading Value
Repeatability: + 0.3% of Reading Value
Max Viscosity: 1,000cP
Max. % of Solids: Clean Service Only, No solids recommended;
Working Temp: 14 to 140' F (-10 to 60'C)
Working Pressure:
PP: 87 psi @ 77'F
43 psi @ 140'F
ECTFE: 116 psi @ 77'F
72 psi @ 140'F
316L SS 116 psi @ 140'F
Cable: 22 AWG, 3 Conductor
Cable Length: Maximum 984' (300m) without signal conditioning

Installation Guidelines
  • The sensor can be installed in any position, horizontally or vertically, although horizontal is preferred. A non-horizontal installation may cause a greater error on the low side of the flow range;

  • Install the sensor with the flow indicator arrow pointing in the direction of the flow;

  • Maximize the distance between the flow sensor and pumps, valves, elbows, or other obstructions that may cause turbulence at the flow sensor. 6" of straight pipe up and downstream of the flow sensor is suggested.


Price: $728.00
Buy Product Online | Visit Store Home
 
Manufactured by Digiflow FlowX3


 Other Items from High Viscosity

  ULF Oval Gear Meter  - Flow Range: 0.044 to 0.44 GPM, Square Wave (Pulse) Output, 5-24VDC Power Supply Required
  ULF Oval Gear Meter  - Flow Range: 0.11 to 0.66 GPM, Square Wave (Pulse) Output, 5-24VDC Power Supply Required

 

  Return To BuyGPI.com - Your GPI Turbine & Oval Gear Flow Meter Store

 

 

e-commerce solutions
Shopping cart powered by MonsterCommerce ecommerce software.